Resources Certifications & Approvals
LPES products are built and tested to comply with the IEC, IS and IEEE standards that govern lightning protection, earthing and surge protection. For each product we state the standard, the test scope and the record you can ask for.

Compliance is not one certificate. It is a chain of records, each one building on the last.
Select a pillar. The applicable edition is confirmed project by project in the design basis.
| Standard | Covers | Where LPES applies it |
|---|---|---|
| IEC 62305-1 / IS/IEC 62305-1 | General principles of protection against lightning | Design basis, lightning protection levels |
| IEC 62305-2 | Risk management | Lightning risk assessment |
| IEC 62305-3 | Physical damage to structures and life hazard | Air termination, down conductors, earth termination |
| IEC 62561 series | Lightning protection system components | Connectors, conductors, earth electrodes, fixings, test joints |
| NBC 2016 | National Building Code of India | Building services requirements |
| Standard | Covers | Where LPES applies it |
|---|---|---|
| IEC 60909 | Short-circuit currents in three-phase AC systems | Fault level studies |
| IEEE 1584 | Arc-flash hazard calculations | Arc flash studies |
| IEC 61000 series | Electromagnetic compatibility and power quality | Harmonics and power quality analysis |
| IEC 60364 | Low-voltage electrical installations | Protection for safety and verification |
| IS 732 | Code of practice for electrical wiring installations | LV installation design in India |
| Standard | Covers | Where LPES applies it |
|---|---|---|
| IS 3043 | Code of practice for earthing | Earthing design in India |
| IEEE 80 | Guide for safety in AC substation grounding | Step and touch voltage, earth grid design |
| IEC 62561-2 and -7 | Conductors, earth electrodes and earthing enhancing compounds | Earthing materials |
| IS 732 / IEC 60364-5-54 | Earthing arrangements and protective conductors | PE conductor sizing and bonding |
| CEA Regulations, 2023 | Measures relating to safety and electric supply | Statutory earthing requirements in India |
| Standard | Covers | Where LPES applies it |
|---|---|---|
| IEC 61643-11 | SPDs connected to low-voltage power systems | Power SPD requirements and tests |
| IEC 61643-21 | SPDs for telecommunications and signalling networks | Data, signal and control line SPDs |
| IEC 61643-31 | SPDs for photovoltaic installations | DC side of solar PV systems |
| IEC 62305-4 | Electrical and electronic systems within structures | Surge protection measures, lightning protection zones |
| IEC 60364-5-53 | Selection and erection: devices for protection against overvoltages | SPD selection and installation |
Standards are named to describe the design and test basis of LPES products and services. Naming a standard is not a claim of certification by its publishing body.
One brand across the whole protection chain, so every component on site traces back to one design basis and one datasheet library.
LIGHTNING · SURGEAC, telecom and solar DC surge protective devices, air terminals, and strip and round conductors.
EARTHINGEarth rods, earthing chemicals and backfill compound, pit covers and earthing record plates.
LIGHTNING · EARTHINGConductor holders, clamps and clamp connectors for strip and round conductors, built to comply with IEC 62561.
Available in four series: LPES BASIC, LPES SMART, LPES PRO and LPES CENTURY.
Records are issued against the specific model, rating and project scope, so that what you receive matches what is installed.
| Record | What it shows | Availability |
|---|---|---|
| Technical datasheet | Item code, family, series, ratings, materials, dimensions and the standard the product complies to. | With every quotation |
| Type test report | Model-specific test results, the standard and clauses tested, and the laboratory that performed the tests. | On request, per model |
| Declaration of conformity | LPES statement that the supplied model conforms to the named standard and rating. | On request, per order |
| Material test certificate | Composition and coating thickness of copper, copper-bonded steel, GI and stainless components. | On request, per batch |
| Routine test and inspection record | Factory checks performed before dispatch, with batch and date. | With dispatch, on request |
| Third-party inspection | Pre-dispatch inspection by the customer or a nominated agency. | By arrangement |
| Site verification record | Continuity, earth resistance and SPD status results against the acceptance criteria. | Within project scope |
Protection claims are easy to make and hard to check. LPES uses three words carefully, and only when the record behind them exists.
How LPES reads a claim: product, standard, scope, issuing body and traceability are all identified before the word is used.
The product is designed and built to the requirements of the named standard. Stated on the datasheet with the standard number.
The model has been tested to the named standard's test sequence. The report names the model, the clauses and the laboratory.
Used only where a certificate exists, with the issuing body, scope, number and validity identified.
Consultants, EPCs and owners use this route for make approval, vendor registration and technical submittals.
LPES lightning protection components are built to comply with the IEC 62561 series, earthing products with IS 3043 and IEC 62561-2 and -7, and surge protective devices with IEC 61643-11, -21 and -31. The applicable standard is stated on each product datasheet.
Yes. Test reports are issued against the specific model and rating. Send the item code or product family and the project name, and LPES will share the applicable records.
Email the specification clause or vendor registration form with the product families required. LPES compiles an approval pack with datasheets, test and conformity records and a compliance matrix.
Yes. Pre-dispatch inspection by the customer or a nominated agency can be arranged before dispatch.
No. A compliant product is one step. The installation also has to be designed, installed and verified to the applicable standard, which is why LPES links product evidence to design and site verification records.
Talk to LPES about a coordinated assessment, from Lightning to Load. Tell us about your facility and an engineer will reply.