Lightning to Load: one method, from the strike point to the last connected load.
Most sites buy lightning protection from one firm, earthing from another and surge protection inside a panel package. The risk crosses those boundaries and nobody owns the gap. Lightning to Load puts the whole chain under one engineering responsibility, in seven stages.




Calculated. Coordinated. Implemented. Verified.
Assess. Design. Specify. Supply. Implement. Verify. Assure.
Select a stage to see what is done and what you receive.
Assess
Understand the exposure before anything is drawn.
- Lightning risk assessment to IEC 62305-2
- Soil resistivity survey
- Audit of existing earthing, lightning protection and SPDs
You receive
Risk assessment report and site audit
Design
Turn the assessment into a coordinated design.
- Air termination and down conductor layout
- Earthing calculation and bonding scheme
- Lightning protection zones and SPD schedule
You receive
Design basis, drawings and calculations
Specify
Fix exactly what is to be supplied and to which standard.
- Bill of quantities with item codes
- Specification text and datasheets
- Approval pack for the consultant
You receive
BOQ, specification and approval pack
Supply
Deliver components built and tested to the product standards.
- Lightning protection components
- Earthing, PE and bonding conductors with accessories
- Surge protective devices and assemblies
You receive
Materials with datasheets and test references
Implement
Install to the drawing, with every joint recorded.
- Installation by trained crews
- Exothermic and mechanical joints to method
- Inspection of concealed parts before they are covered
You receive
As-built drawings and joint register
Verify
Prove by test that the installation performs.
- Continuity and earth resistance tests
- Loop impedance tests for every source
- Visual inspection against the design
You receive
Test report with each item marked
Assure
Keep it performing for the life of the facility.
- Periodic inspection and testing
- SPD and strike monitoring
- Records kept current for the inspector
You receive
LPES Protection Passport, kept up to date
Four pillars. Connected protection. Clear accountability.

Lightning Protection
Intercept the strike and carry the current to earth without damage.
Explore
Power Protection
Clear faults in time through PE conductors, bonding and protective devices.
Explore
Earthing Protection
Disperse current safely and hold touch and step voltage within limits.
Explore
Surge Protection
Stop the surge at each zone boundary before it reaches the equipment.
ExploreThe LPES Protection Passport.
Every Lightning to Load project ends in one controlled dossier for the facility: the risk assessment, the design basis, as-built drawings, product data, test reports and the inspection history. It is what an inspector, an insurer or a new plant engineer asks for, in one place.
- One record for lightning protection, earthing and surge protection
- Updated at every inspection
- Each item marked complies, does not comply or not demonstrated

About the method.
Do I have to take all seven stages?
No. Many clients start with an assessment or a design review and continue from there. The stages are built to hand over cleanly. Request a site assessment
Can Lightning to Load be applied to an existing plant?
Yes. It starts with an audit of what is installed and a gap list against the current standards. Periodic inspection and testing
What is different from buying the three packages separately?
One party calculates, coordinates and verifies the whole chain, so the earthing matches the lightning protection and the SPDs match both. Global earthing system
Understand your risks. Coordinate your protection. Know who owns each responsibility.