Design guides for every stage, from Lightning to Load.
The LPES library follows the four pillars: Lightning, Power, Earthing and Surge Protection. Each guide explains the method, cites the standard and ends at the product family that builds it.

Four shelves. One system.

Lightning Protection
Intercept, conduct, disperse.
Rolling sphere method
Placing air terminals on any structure with the general method.
Read the guideDesign methodMesh method for large roofs
Grid layouts for industrial and warehouse roofs.
Read the guideSolution guideMetal and PEB roofs
When the sheet can be the air termination and when it cannot.
Open the solutionSolution guideIsolated lightning protection
Keeping lightning current off the structure.
Open the solutionSolution guideHazardous areas
Lightning and static protection for tanks and process plant.
Open the solutionProductsAir termination to test joint
The LPES lightning protection range by function.
Browse the range
Power Protection
Clear the fault, limit the touch voltage.
Equipotential bonding
Main and supplementary bonding for buildings and plants.
Open the solutionSolution guideStep and touch voltage control
Keeping people safe at down conductors and substations.
Open the solutionCalculatorPE conductor size and loop impedance
Size the conductor, then check the device trips in time.
Use the tools
Earthing Protection
One network, proven by test.
Foundation earth electrode
The electrode built into the structure.
Open the solutionSolution guideGlobal earthing system
Interconnecting every earth on a plant.
Open the solutionSolution guideSubstation grid earthing
Grid design to IEEE 80 and IS 3043.
Open the solutionSolution guideRod, ring and plate earthing
Choosing the electrode for the soil.
Open the solutionProductsElectrodes, conductors and joints
The LPES earthing range, including PE and bonding conductors.
Browse the range
Surge Protection
Zone by zone, to the load.
Lightning protection zones
Dividing a facility into zones and protecting each boundary.
Read the guideSolution guideSurge protection by zone
A coordinated SPD system from entrance to equipment.
Open the solutionSolution guideRooftop solar PV
DC and AC side protection for PV plants.
Open the solutionProductsType 1 to Type 3, power and data
The LPES surge protection range.
Browse the rangeThe LPES Earthing Handbook, India.
A practical guide to earthing in India, aligned to IS 3043:2026: system earthing, protective conductors, electrodes, bonding, testing and the mistakes found most often on site.
- Written for design engineers, contractors and EHS teams
- Worked examples for loop impedance, conductor sizing and electrode resistance
- Checklists for design review and site inspection
The handbook is in preparation. Register and we will send it on release.

Tell us the structure and the question.
We will send the guide that fits, or write a short note for your case.